LDEC

Container Closure Integrity Tester-DHS 640 Vacuum decay integrity tester

Container Closure Integrity Tester-DHS 640 Vacuum decay integrity tester

DHS640 is a vacuum decay method container closure integrity tester with dual sensor and dual cycle detection technology. The method complies with USP1207, Technical Requirements for Quality and Efficacy Consistency Evaluation of Generic Chemical Drug Injectable Agents and Technical Guidelines for Study of Sealing of Chemical Drug Injectable Agent Packaging System.

The tester host is connected to a specially designed chamber that accommodates the packaging under test. The packaging is placed in the experimental chamber requiring vacuum extraction, where the chamber is evacuated. By detecting the differential pressure (pa) during the pressure-holding phase of the container, the system monitors potential leaks and determines product compliance based on method-developed thresholds. This configuration can detect packaging leaks as small as 1μm. Furthermore, its dual-cycle detection mode enables simultaneous micro-leak detection and large-leak detection capabilities.

 

 model

DHS 640

Technical parameters

Suitable packaging

Vials, ampoules, pre-filled syringes, cartridges, infusion bottles/bags, BFS, eye drops, etc

 

Applicable products

Freeze-dried, powder, solution, etc

 

Purpose of testing

Prevent microbial invasion risk

 

 test method

Vacuum attenuation (optional pressure/vacuum attenuation dual mode)

 

Test principles

Dual sensor double cycle differential pressure detection

 

 testing standard

ASTM F2338-09 (Vacuum attenuation); ASTM F2095 (Pressure attenuation)

 

 detection sensitivity

Maximum 0.01sccm (equivalent aperture about 1 μm)

 

Test chamber

Custom cavities are available according to user specifications, which can be made of 316L or plexiglass

 

 detection result

Qualification/Non-qualification; Quantitative mbar Pa

 

 software

It has permission management, audit log and automatic data storage functions, which meet the requirements of 21CFR Part 11

 

System validation

IQ/OQ/PQ, method development and method validation

 

 option

3Q verification/minimal flowmeter (mass flow)

 

 language

Chinese/English

 

Power/Power

100-240V AC/50W

 

 air supply

Vacuum is below 1mbar

 

Environmental requirements

 working temperature

+10~+45

 

 

Storage temperature

0~+60

 

Mainframe size (L*W*H)

420*420*380mm

 

Host weight

25kg /55 lbs

 

 noise level

< 53db